Determination of hair nicotine by gas chromatography-mass spectrometry

Date Published:
2009
Citation-Indexed Journal:
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, Volume 877, Issue 3, 15 January 2009, Pages 339-342
Citation:
Determination of hair nicotine by gas chromatography-mass spectrometry
Authors:
Man,C.N.,
Ismail, S.,
Harn, G.L.,
Lajis, R.,
Awang, R.
Abstract:
Hair nicotine is a known biomarker for monitoring long-term environmental tobacco smoke (ETS) exposure and smoking status.

In general, hair nicotine assay involves alkaline digestion, extraction and instrumental analysis. The gas chromatography-mass spectrometry (GC-MS) assay currently developed has shown to be of high throughput with average ∼100 hair samples being extracted and analyzed per day. This was achieved through simplified extraction procedure and shortened GC analysis time. The extraction was improved by using small volume (0.4 mL) of organic solvent that does not require further evaporation and salting steps prior to GC-MS analysis. Furthermore, the amount of hair utilized in the extraction was very little (5 mg) while the sensitivity and selectivity of the assay is equal, if not better than other established methods. The linearity of the assay (r2 > 0.995), limit of quantitation (0.04 ng/mg hair), within- and between-assays accuracies and precisions (<11.4%) and mean recovery (92.6%) were within the acceptable range.


s utube s fb


  >  Penafian   
  >  Dasar Privasi
  >  Piagam Pelanggan    
  >  Dasar Keselamatan
  >  Peta Laman
  >  Galeri
  >  Hakmilik   
  > 
iconadminblack icfb ictwit icrss icyoutube


 

  •       E-PAYMENT
    qrcode
  • QUICK LINK
    >  Kampus Induk

    >  Kampus Kejuruteraan
    >  Kampus Kesihatan
    >  Campus Online
    > Emel Rasmi USM
    >  Administrator

    .
  • QUICK LINK
    > Kem. Kew. Malaysia

    > Kem. Pendidikan Malaysia
    > Jab. Akauntan Negara
    > Jab. Kastam Malaysia

    > Bank Negara Malaysia
    > MSC Malaysia
  • CONTACT US
    National Poison Centre
    Universiti Sains Malaysia
    11800 Penang
    Malaysia

    cont 02: +604-653 2265
    fax: +604-656 8417
    cont 03: This email address is being protected from spambots. You need JavaScript enabled to view it.

    .
  • 059091
    Hari iniHari ini347
    SemalamSemalam1387
    Minggu IniMinggu Ini5834
    Bulan IniBulan Ini5834
    Sepanjang HariSepanjang Hari59091
    .

Hakcipta Terpelihara 2020 -  © 2018 Pusat Racun Negara. All Rights Reserved.